Rich industrial I/O interfaces (Analogue 4-20mA, 0-10V, Digital I/O, Serial RS232, RS485,) Input for PT100 temperature sensor Intelligent triggering system with autonomous operation
The UC300 IoT controller is used for remote control and data acquisition in industrial environments.
It allows data acquisition from various devices. It contains multiple input and output interfaces such as analogue inputs, digital inputs, serial ports, relay outputs and PT100 temperature sensor inputs. Information and data are then transmitted remotely via the LoRaWAN® network.
The UC300 controller supports multiple trigger conditions and actions that can operate autonomously even when the network is interrupted.
Combined with our cloud-based IoT data management solution Telemesure.net, users can view and manage all remote measurement data and receive real-time alarms or notifications via a browser or remote mobile device.
Adopting an industrial design and IP30 metal housing, the UC300 is widely used in indoor applications such as smart factories (Smart Industry 4.0), smart buildings and smart cities for urban asset management.
Features
Easy to connect with various wired devices via DIO/AI/RS232/RS485/PT100
Supports LoRaWAN® wireless communication
Multiple trigger conditions and actions
Built-in watchdog for stable device operation
Industrial metal housing with wide operating temperature range
Ultra long range wireless transmission up to 10 km line of sight
Compatible with LoRaWAN® 868Mhz Class A gateways and standard LoRaWAN® network infrastructure
Quick and easy management with Telemesure.net IoT Cloud solution
Specifications
Wireless transmission: LoRaWAN® technology
1 × 50 Ω SMA antenna connector (center PIN: SMA female)
Data Interfaces
Interface type 3.5 mm terminal block
IO ports
Ports 4 × DI + 2 × DO
Digital input Opto-isolated digital inputs, 3-24VDC (pulse counter support)
Digital output SPDT relay contact 3A@DC Max: 30 V or AC Max: 250 V
Serial port
Ports 1 × RS232 + 1 × RS485
Baud rate 1200~115200 bps
Protocol Transparent (RS232), Modbus RTU (RS485)
Analogue input
Ports 2 × 4~20 mA + 2 × 0~10 V
Resolution 12 bits
Analogue input (RTD)
Ports 2 × PT100 RTD input
Input connections 2, 3 wire
12-bit resolution
Range -200°C ~ 800°C
Other ports
Configuration port 1 × Type-C
LED indicators 1 × System, 1 × ACT
Built-in watchdog, timer
Physical Features
Power connector 3.5 mm terminal block
Power supply 5-24 VDC
Colour and material: Black, metal
IP30 protection
Operating temperature -20°C ~ 60°C (-4℉ to +140℉)
Relative humidity 0% ~ 95% (non-condensing) at 25°C/77℉